Back to BlogSafety

Sockets Not Working But Lights Still On? What to Check in a Nottingham Home

Somo Electrical Team23 October 20266 min read

If your sockets have stopped working but the lights are still on, the socket circuit has failed and the lighting circuit has not — they are separate circuits on separate breakers, which is why one can die while the other carries on. In most homes the cause is something tripping, one plugged-in appliance faulting, or a connection failing in the socket wiring.

It is one of the calls we take most often from Nottingham homes, and the first two account for most of them. The third is work for a registered electrician — nothing below asks you to open a consumer unit, a socket or a plug.

Why have my sockets stopped working but the lights are still on?

Lighting, sockets, cooker and shower each have their own breaker in the consumer unit — the box of switches people still call the fuse board. So a socket fault leaves the lights alone, and the supply is clearly live.

  • Something has tripped. The socket circuit's breaker, or the RCD — the device that cuts power when it detects current leaking to earth. From the front of the board a tripped switch is sometimes obvious and sometimes barely out of line.
  • One appliance has faulted. A failing kettle element, a water-damaged charger or a garden tool that got wet takes the circuit down, and keeps taking it down until it is unplugged.
  • A connection has failed. A terminal worked loose, or a cable nicked by a screw, breaks the circuit with nothing tripping at all. This one needs testing: a poor connection still carrying current gets hot.

How much of the house is dead, and what does that tell you?

Work out the extent first. It narrows the fault down more than anything else you can tell us.

  • One socket, the rest fine. Usually that socket or its connection — or a spur, a socket wired off the circuit rather than part of it.
  • One room, or a run of rooms. A break at one point, with the sockets past it dead — common where cables have been disturbed by past building work.
  • A whole floor, or every socket. Many homes have one socket circuit upstairs and another down; if all are dead it is usually the RCD.
  • Sockets and lights off, street dark too. Not your installation. The free power cut line, 105, reaches the network operator for your postcode.

What can I safely check first?

None involves touching any wiring. Work down the list and stop at step 6.

  1. Try the appliance somewhere else. Plug it into a socket you know works in another room. A good share of these calls end there, with a sound socket and a dead appliance.
  2. Map the dead area. Try a lamp you know works in every socket and write down which are dead. That list is the most useful thing you can hand an electrician.
  3. Unplug everything on the dead sockets, including what lives permanently plugged in out of sight: fridge, freezer, washing machine, chargers.
  4. Look at the consumer unit with the cover on. Does any switch sit out of line with its neighbours? Check for a second board — some all-electric homes have one.
  5. Reset once. Push a tripped switch fully off, then firmly back on, once. If power returns, plug things back one at a time; whatever trips it again is your fault. If it will not reset, stop.
  6. Stop. If nothing has tripped and the sockets are still dead, the next step is testing wiring that may be live. That is the point to call a registered electrician.

What not to do: take the cover off the consumer unit, unscrew a socket front, hold a tripping breaker in, or keep using a socket that is warm, marked or smells.

Which dead-socket faults are urgent, and which can wait?

Urgency is set by what you can see, smell and feel at the socket. Sockets that work on and off belong in the first two rows: intermittent means a connection making and breaking under load, and that produces heat.

How urgentWhat you are seeingWhat to do
Someone out todayA burning smell, scorch marks round a socket or plug, anything warm, buzzing, a plug that sparked, a shock or tingle, or power lost after water got inStop using that circuit, call an electrician the same day. Smoke means 999 first
Book it in this weekA circuit dead with nothing tripped, a breaker that resets then trips later, or sockets working intermittentlyA normal appointment. Leave those sockets unused and bring your list
Not an emergencyOne appliance that fails in every socket you try, or one dead socket with no smell, marks or warmthReplace the appliance. A dead socket still needs an electrician, but it can wait

Why does a ring circuit go dead in places and still work elsewhere?

Most socket circuits in British homes are wired as a ring: the cable leaves the consumer unit, calls at each socket in turn and returns to the same breaker, so every socket is fed from two directions. One break anywhere in the loop usually leaves everything still working, and nobody notices.

Two breaks is when it shows: the sockets between them go dead while the rest of the house is unaffected, which usually means the circuit has had a problem for longer than today. A fused connection unit — the small switched plate with a fuse in it, often behind a washing machine — hides a fault the same way.

In the terraces and inter-war semis around West Bridgford, socket circuits have often been extended twice over, so a dead run usually traces back to a join made during a conversion rather than to the original wiring.

What will an electrician do about sockets with no power?

Fault finding is a diagnostic visit rather than a fixed job, so it is normally charged by time. The usual order: confirm which circuit the dead sockets are on, test it for continuity and insulation resistance, then narrow the break down until the failed connection shows. Often the repair is one terminal remade.

Where the circuit itself is the problem — brittle insulation, a ring broken in several places, no earth continuity — the next step is usually an electrical installation condition report, an EICR, which says whether this is a repair or something larger. Our guides to the signs a fuse board needs replacing and a new consumer unit or a full rewire cover that decision. Check whoever you call is registered with a competent person scheme: NAPIT's find-an-installer search and the Electrical Safety First register both check a number for you.

Frequently asked questions

Is it safe to keep resetting the breaker if the sockets come back on?

No. A breaker or RCD that trips is doing its job, and resetting it puts the circuit back into the fault. Reset once, after unplugging everything on that circuit. If it trips again, leave it off and have the circuit tested — repeated resetting is how an inconvenient fault turns into a hot one.

Can one faulty appliance really stop every socket working?

Yes, and it is one of the commonest causes. A fault inside an appliance leaks current to earth, the RCD detects it, and power goes off to every circuit that device protects. The appliance often looks and sounds normal, so adding things back one at a time is what finds it.

Do dead sockets mean my house needs rewiring?

Not on their own. Most dead sockets trace back to one appliance, one tripped device or one failed connection, and the repair is small. Rewiring becomes the question only when testing shows the circuit is at the end of its life: brittle insulation, damage in several places, no earth continuity.

Can I run an extension lead from a room that still works?

For a short while, yes: a lamp or a phone charger from a socket on a working circuit is reasonable while you wait for an appointment. Do not run a washing machine, heater or tumble dryer that way, do not daisy-chain leads, and do not leave one trailing through a doorway for weeks.

Socket fault finding with Somo Electrical

Somo Electrical is a NAPIT-registered electrical contractor, registration number 33320, working across Nottingham and nearby including West Bridgford. We trace dead and intermittent socket circuits and say plainly when one needs more than a repair.

Call 07733 666004 for an emergency electrical repair, or use our online quote form for anything that can wait. Fault finding is charged by time; our guide to what an electrician charges per hour explains how. If a breaker or RCD keeps tripping, start with why an RCD keeps tripping.

Written 23 October 2026. It states no price and no regulation, standard or legal duty — causes, symptoms and process only. The urgency signs are general electrical practice, not a reading of any standard: no primary source could be opened from the environment it was drafted in, so nothing here says what a regulation requires. The power cut number 105 comes from published UK guidance, unverified this run. Testing and repairing fixed wiring is work for a qualified, registered electrician.

fault findingsocketssafetydomesticWest Bridgford

Need Help With This?

Our NAPIT registered electricians are ready to help. Get a free, no-obligation quote today.

Ready to Transform Your Electrical System?

Contact us today for a free, no-obligation quote. Our team of NAPIT registered electricians is ready to provide you with expert service.

  • Free, no-obligation quotes
  • NAPIT registered electricians
  • Full warranty on all work
  • Emergency service available
  • Commercial and residential solutions