The power keeps tripping in a Nottingham shop or office for one of three reasons: a circuit is carrying more than it was built to carry, one piece of equipment has developed a fault, or enough small leakages to earth have built up that a protective device can no longer tell normal running from a genuine fault. What tripped, and when, usually narrows it to one of the three.

Finding the cause and putting it right is work for a qualified, registered electrician. Somo Electrical is NAPIT-registered, registration number 33320, and you can check any contractor on the NAPIT or NICEIC register rather than taking a logo at face value. Workplace electrical safety duties sit with HSE.

Why does the power keep tripping in my shop or office?

  • Overload. A circuit is asked for more than it was designed to supply — usually something added since the premises were wired: a second fridge, a panini grill, a heater under the counter in October.
  • A fault in one appliance. A failing motor, a water-damaged heater, a frayed lead on something moved daily. Kitchens see far more of this than offices.
  • Accumulated leakage. Electronic equipment each leaks a tiny amount to earth as a normal part of how its power supply works. One device is nothing; a room of tills, screens, routers and chillers on one protective device adds up, and once the standing total sits near where that device operates, almost anything tips it over.

The third is why a premises fine for years starts tripping with nothing obviously broken, and the one most often misread as a faulty device. The home version is in our guide to why an RCD keeps tripping; in a business, the difference is how much is plugged in.

Which device tripped, and what does that tell you?

Find out what actually operated first — it is the most useful thing you can tell an electrician on the phone.

  • One small switch off, everything else on. A single circuit's protective device has operated — overload or a fault on that circuit, which tells you where to look.
  • A group of circuits off together. A device covering several has operated, pointing at leakage or a fault in the group — why a till can go off because of something in a back room.
  • Everything off, lights included. Either a main device has gone or the supply has. If neighbouring units are dark too it is not your installation — call 105, the free power cut line, which routes to the right network operator for your postcode.
  • Nothing visibly tripped but equipment is dead. A fault to investigate, not a puzzle to solve by switching things — see the first hour of a commercial emergency.

What can you safely check before calling an electrician?

This stops where the next step belongs to an electrician. Nothing in it means opening a board or working on anything live.

  1. Look for obvious danger first. A burning or fishy smell, a warm or discoloured socket, scorch marks, buzzing, or anyone who has had a shock. If so, leave the circuit off, keep people away and call an electrician — do not go looking for the cause.
  2. Write down what was running in the minute before it went, and which part of the premises went off.
  3. Switch off and unplug everything on the affected area, including what is behind the counter.
  4. If you are authorised to operate the board, try resetting once. One attempt. If it holds, bring equipment back one item at a time and note what is on when it goes again.
  5. If it trips again, or will not reset, stop. That is a fault to be found with instruments, not by trial and error.

Two things nobody should do, whatever the pressure to get the tills back on: never hold, tape or wedge a protective device into the on position, and never fit a larger one to stop it operating — it is sized to protect the cable in your walls. Each reset also puts the fault back onto the circuit.

Which tripping is urgent, and which can wait until morning?

  • Call out of hours. Burning smells, heat or scorching, visible damage, water getting into anything electrical, anyone shocked, a trip taking out the fire alarm or emergency lighting, or anything leaving the premises unsafe to trade in.
  • Call first thing, circuit off meanwhile. A circuit that trips the moment it is reset, one that takes out refrigeration or anything else holding stock, or one recurring through the day.
  • Book it in — but do book it in. An occasional trip you can live with, or a pattern that crept in over months. These get reset and forgotten for a year, and are cheaper to find before they become the first category.

If stock is at risk, move it before you start diagnosing. A chiller circuit that trips overnight is a stock loss as much as an electrical fault, and usually dwarfs the callout.

Who can get to the board in a leased unit?

Many Nottingham high-street units have their own board inside the demise, plus an intake and metering position in a shared cupboard or riser controlled by the landlord or managing agent. If what operated sits in that shared space you may have no right of access and no key, so your electrician needs the agent's co-operation. Ask who holds that key before you need it.

Who pays is a question about your lease, not about electrics. An electrician can say what failed; whether the repair falls to you or the landlord comes out of the repairing covenants, and belongs with your managing agent, your insurer and, if disputed, a solicitor.

Frequently asked questions

Is it safe to keep resetting a breaker that trips in a shop?

No. One reset to see whether it was a one-off is reasonable if you are authorised to operate the board. After that, each reset puts the fault back onto the circuit — and if the cause is damaged cable, you are repeating what caused it. Trips twice, leave it off.

Why does the power trip first thing in the morning when we open up?

Opening up is the heaviest moment of the day: lighting, heating, refrigeration, grills and screens all switching on within minutes, with motors drawing their highest current as they start. That points at a circuit close to its limit rather than a broken appliance — which is why it is fine by mid-morning.

Can one faulty appliance really take the power out across a whole shop?

Yes, if several circuits share one protective device. A fault in a single kettle or chiller in a back room can operate a device covering the till, the lights and the office at once. It is why the fault often seems nowhere near what went off.

Does a tripping circuit mean our premises will fail an inspection?

Not by itself. Tripping is a symptom; a report records the condition of the installation and what is found on the day. Tripping caused by too much equipment on one protective device is usually a distribution issue rather than a danger, while a trip caused by damaged cable or water ingress is a different matter — but how either is recorded is a judgement for the inspecting electrician.

Fault finding for Nottingham business premises with Somo Electrical

Fault finding is a measured process rather than a parts swap: standing leakage measured with instruments while equipment runs, so accumulated leakage can be told apart from a fault, and circuits split and tested individually. Where too much sits on one device, the fix is redistributing circuits or giving heavy loads their own protection — a board alteration, and work for a registered electrician. If the tripping arrived with other signs of an ageing installation, see commercial fixed wire testing and how often a commercial property needs an EICR; where the suspect is one appliance, portable appliance testing covers it.

Somo Electrical is a NAPIT-registered electrical contractor, registration number 33320, working with shops, offices, cafés and small industrial units across Nottingham including Beeston. Call 07733 666004 or use our online quote form. We cover commercial electrical work, emergency repairs, testing and inspection and distribution board work.

Written 30 October 2026. No legal duty, inspection interval, wiring standard, regulation number or leakage threshold is stated above — no primary source could be reached from the environment this was drafted in, so workplace duties go to HSE and anything standard-specific to your electrician. Nothing here describes work for a householder or a member of staff to carry out. What to check in a contractor is competent person scheme registration, on the scheme's own register rather than on their website.

commercialfault findingbusiness premisestrippingBeeston

Need Help With This?

Our NAPIT registered electricians are ready to help. Get a free, no-obligation quote today.

Ready to Transform Your Electrical System?

Contact us today for a free, no-obligation quote. Our team of NAPIT registered electricians is ready to provide you with expert service.

  • Free, no-obligation quotes
  • NAPIT registered electricians
  • Full warranty on all work
  • Emergency service available
  • Commercial and residential solutions